Progetto FJ SCT (Flat Jack for Shear Compression Test)
The mechanical parameters that characterize the shear behavior of masonry are fundamental for assessing structural safety, both in seismic and static conditions...
Vittoria bridge in Bassano del Grappa (VI)
Reinforced concrete condition was verified through access and positioning system by ropes. Structural analysis was carried out through sufficient sampling of m...
Alpini bridge in Bassano del Grappa (VI) - analysis
Laser scanner technology was used to fully analyse the Alpini bridge, 3D scans being taken with an HDS 7000 (Leica Geosystems) scanner which can identify a spac...
Catholic University of “Sacro Cuore” in Milano -...
The diagnosis concerned the masonry and reinforced concrete structures of the Gregorianum building in the west wing of the Catholic University of Milano to anal...
Valtellina Cultural District
The Valtellina cultural district project is a long term plan co-financed by the CARIPLO foundation aiming at valorising cultural heritage as a mile stone toward...
former “Politeama” theatre in Massa Carrara
Diagnosis was carried out to analyse the stress and mechanical characteristics of brickwork masonry pillars inside the building featuring worrying cracking. Sin...
Blasi Schulhaus in Basel, Switzerland - testing for seismic ...
The diagnosis was carried out in order to bring a school building up to comply seismic protection levels and was managed as follows: measurement of structura...
Old Chimney of "La Baia" residential block in Cremia (CO)
Structural diagnostics were carried out to obtain an LC3 level of knowledge as specified in the Italian Seismic Code To reach this level, geometrical surveys w...
Scaligero castle in Ponti sul Mincio (MN)
This is a 13th century castle built on a moraine rock hilltop with an irregular plan, longer than it is wide, with five towers the main of which looking south e...
Colloredo castle in Monte Albano (UD)
Analysis was carried out to characterize non reinforced masonry samples and those reinforced by grouting or by insertion of engineering tie rods in order to cho...
S. Maria school in Livigno (SO) – seismic hazard analysis
The building is made up of a main section from 1954 and an extension from 1981. The geological-geometrical analysis aimed at characterizing the area adjacent t...
structural analysis of private buildings in Modena province ...
FOPPOLI MORETTA e ASSOCIATI carried out structural analysis of many public and private buildings located close to the epicentre of the Emilia earthquakes of 20t...
Concordia sul Secchia (MO) oratory
Following the earthquakes of 20th and 29th May 2012, the damaged building needed to be rehabilitated for public use. With FMeA co-ordination, the first phase wa...
S. Romerio church in Brusio (Switzerland) – diagnostic
The S. Romerio church stands 1800 metres above sea level on a vertical cliff face over the Poschiavo lake in Switzerland and enjoys special status in as much as...
Torrazzo bell-tower in Cremona
The tower is 112 m tall; up to 70m, the tower is square plan brickwork, from 70 to 112 m it is an octagonal spire tower known as "ghirlandina". The inspection ...
Parella castle - TORINO
Diagnosis was to determine masonry stress through flat jack testing and deformation in masonry structures and the estimation of their compression strength throu...
MONUMENTEN WATCH ITALY Project
The recognition that regular maintenance can help contain—at lower cost and with reduced use of energy and materials—the progression of building deteriorati...
SS. Gervasio and Protasio bell-tower in Sondrio
Following the sudden bending of the great cross at the top of the roof in 2005, it became necessary to substitute the wooden structure and covering of the bell-...
Giotto bell-tower Florence
The diagnostics carried out aimed to collect dimensional and compositional information on the structure and to determine the stress on the walls in specific pos...
S. Ignazio church in Ponte Valtellina (SO)
To collect all information necessary for the static analysis of the structure the following operations were carried out: sub-vertical boring, crack survey, stru...
S. Sindone chapel in the Turin cathedral
During reinforcement work, it became necessary to collect information concerning the structural solidity of 6 arches of the chapel dome. Tests were carried out ...
Canali Mansion in Tovo (SO) restoration and valorisation
The listed building makes up part of the central historical area of Tovo. The building was partly demolished with the rear façade being completely ruined. The...
Canali Mansion in Tovo (SO) - structural improvement
The listed building suffered a completely ruined rear facade. The previous overall volume was reconstructed using a new structure entirely made with glass and ...
Besta Mansion in Bianzone (SO)
Analysis involved continuous sub-vertical and horizontal coring, endoscopic video inspections in bore holes, flat jack and parallel flat jack testing, radar sur...
Castelseprio (VA) archeological park - structure
The S. Giovanni monastery in Castelseprio, until recently used as nothing more than an agricultural storage building, was returned to full use as the museum for...
Valdone bridge in Valmalenco (SO)
A structural monitoring system was set up with fixed instruments inside and outside the bridge deck. Analysis foresaw both internal and external structural ins...
Watering plant of the Middle Valtellina
Project phases were aimed at improving in water management for agricultural purposes as follows: the up-grading of cathode protection irrigation systems in t...
Structural analysis on heritage buildings in the centre of L...
FOPPOLI MORETTA e ASSOCIATI carried out analysis for the characterization of many heritage buildings and other structures damaged by the earthquake of 6th April...
Pallata tower in Brescia - analysis
Analysis foresaw continuous sub/vertical and horizontal coring, video probe prospecting, single and parallel flat jack testing and the installation of a structu...
Access road to the sports centre in Tirano (SO)
The extra-urban category F road giving access to the Tirano sports centre is a two lane road (width 7.00 m plus edging), with a length of around 950 m. Given t...