Besta Mansion in Bianzone (SO)
Analysis involved continuous sub-vertical and horizontal coring, endoscopic video inspections in bore holes, flat jack and parallel flat jack testing, radar survey for the detection of the geometric extrados of the vaults and analysis of cracks.
Structural monitoring with fixed instruments for crack measurement and long base extensimeter for movements in counter positioned structures was carried on over a two year period. A structural Finite Elements Model was implemented in order to assess the structural condition of the building.
Data sheet
- client: Bianzone (SO) city council – Lombardy Regional Heritage and Landscape Directorate
- location: Bianzone (SO)
- activities: continuous coring, endoscopic video inspection in test holes, flat jack testing, vault analysis, structural monitoring Finite Elements Modelling
- period: August 2009 – July 2011
Mansions and heritages buildings
Canali Mansion in Tovo (SO) - structural improvement
The listed building suffered a completely ruined rear facade. The previous overall volume was reconstructed using a new structure entirely made with glass and ...
Besta Palace in Teglio (SO) – seismic hazard analysis
The diagnostic campaign carried out meant it was possible to achieve a confidence factor FC=1,21. Seismic vulnerability analysis was carried out in two phases:...
Besta Palace in Teglio (SO) – structural improvement o...
The planning of the structural improvement of the wooden structures on the second floor of the west wing of Besta Palace started from the thorough study of thei...