Besta Palace in Teglio (SO) – seismic hazard analysis
The diagnostic campaign carried out meant it was possible to achieve a confidence factor FC=1,21.
Seismic vulnerability analysis was carried out in two phases:
- Preliminary analysis of seismic vulnerability at level LV1 through simplified mechanic modelling as foreseen by Italian Seismic Guidelines for Heritage Buildings
- Seismic vulnerability analysis at level LV2 for the identification of particularly vulnerable localized factors (macro-elements).
As prescribed when working with listed buildings, the analysis was implemented through the SIVARS standard computer application for seismic risk evaluation of public heritage buildings.
Data sheet
- client: Lombardy Regional Heritage and Landscape Directorate
- location: Teglio (SO)
- volume: 11.500 m3
- period: 2009-2015
- activities: structural analysis and monitoring, seismic safety assessment
Mansions and heritages buildings
Besta Mansion in Bianzone (SO)
Analysis involved continuous sub-vertical and horizontal coring, endoscopic video inspections in bore holes, flat jack and parallel flat jack testing, radar sur...
Besta Palace in Teglio (SO) – structural improvement o...
The planning of the structural improvement of the wooden structures on the second floor of the west wing of Besta Palace started from the thorough study of thei...
Besta Palace in Teglio (SO) – analysis
Geological and geo-technical tests were carried out to analyze the adjacent area to the building for seismic risk according to Italian national and regional Sei...