Valdone bridge in Valmalenco (SO)
A structural monitoring system was set up with fixed instruments inside and outside the bridge deck.
Analysis foresaw both internal and external structural inspections, as well as the planning and monitoring system and its installation. Deformation, changes in cracking, changes in crack size, changes in joint opening size, thermal probes for concrete temperature and for air temperature readings and an easily accessible converter control panel were all installed. The system will operate for more than 5 years thus allowing a great quantity of storage of data and its subsequent statistic analysis.
Data sheet
- client: Sondrio province
- location: Valmalenco (SO)
- activities: structural monitoring system installation and management
- period: 2011 – 2017
Bridges
Alpini bridge in Bassano del Grappa (VI) - analysis
Laser scanner technology was used to fully analyse the Alpini bridge, 3D scans being taken with an HDS 7000 (Leica Geosystems) scanner which can identify a spac...
Rio Bondai medieval bridge in San Lorenzo, Banale (TN)
Bridge masonry work was in an evident state of disrepair and analysis aimed at collecting metric and material information concerning masonry foundation structur...