Home › Portfolio › Schools, hospitals and social care centres › Catholic University of “Sacro Cuore” in Milano - testing for seismic hazard analysis

Catholic University of “Sacro Cuore” in Milano - testing for seismic hazard analysis

Catholic University of “Sacro Cuore” in Milano - testing for seismic hazard analysis

Previous Next

The diagnosis concerned the masonry and reinforced concrete structures of the Gregorianum building in the west wing of the Catholic University of Milano to analyse their seismic hazard.

The following operations were carried out:
- flat jack testing to determine the masonry stress;
- parallel flat jack testing to detect the masonry deformation characteristics;
- shear test on masonry performed with the use of flat jack with FJ-SCT technique;
- sonic testing for masonry typology detection;
- chemical - physical - petrographic analysis of mortar;
- compression tests on brickwork sampled from the masonry;
- SonReb testing for concrete resistance and compression values;
- endoscopic video inspection for the detection of small dimension masonry details;
- load testing on attic structures with the use of hydraulic jacks

Data sheet

  • client: Università Cattolica del Sacro Cuore - MILAN
  • location: Milan
  • activities: diagnosis of seismic risk on the Gregorianum building
  • period: 2015
Schools, hospitals and social care centresSchools, hospitals and social care centres
Other projects

Schools, hospitals and social care centres

Sondrio hospital: south wing - fire safety planning

Sondrio hospital: south wing - fire safety planning

The operation foresaw the completion of the Sondrio hospital planning to come up to date with fire-safety norms and obtain the fire safety certification. The p...

Blasi Schulhaus in Basel, Switzerland - testing for seismic hazard analysis

Blasi Schulhaus in Basel, Switzerland - testing for seismic ...

The diagnosis was carried out in order to bring a school building up to comply seismic protection levels and was managed as follows: measurement of structura...

S. Maria school in Livigno (SO) – seismic hazard analysis

S. Maria school in Livigno (SO) – seismic hazard analysis

The building is made up of a main section from 1954 and an extension from 1981. The geological-geometrical analysis aimed at characterizing the area adjacent t...

FOPPOLI MORETTA E ASSOCIATI
società di ingegneria s.r.l.
Piazzetta L. Trombini 5, 23037 Tirano (SO)
C.F. / P.IVA / R.I. 00846800142
Codice INARCASSA SI002933
C.S. € 50 000 i.v

Cookie policy | Privacy Policy
Change your cookie settings

+39 0342 704827
posta@foppolimoretta.it
Reserved Area

© 2026 FOPPOLI MORETTA E ASSOCIATI
  • Home
  • Our company
  • Services
  • Portfolio
  • News
  • Video
  • Publications
  • Press review
  • Contacts

designed by IceLab