posta@foppolimoretta.it
+39 0342 704827
ItalianoEnglish
FOPPOLI MORETTA E ASSOCIATI
  • Home
  • Our company
    • About us
    • Team
  • Services
    • Design and construction supervision
    • Structure
    • Technical systems and large-scale projects
    • Safety coordination
    • Testing and monitoring
    • Vulnerability assessment
    • BIM and digital construction process
    • Research and development
  • Portfolio
  • Extra
    • News
    • Video
    • Publications
    • Press review
  • Contacts

Portfolio

Home › Portfolio › Vulnerability assessment › Castelseprio (VA) archeological park – seismic hazard analysis

Castelseprio (VA) archeological park – seismic hazard analysis

Castelseprio (VA) archeological park – seismic hazard analysis

Previous Next

Seismic risk for the San Giovanni monastery in Castelseprio archaeological park was evaluated at level LV1 with a level LV2 integration for possible vulnerable macro-elements. A linear analysis was also carried out on the new wooden structure on the building’s south face.

The building is used mainly as a museum and exhibition space and that leads to its classification as a type 2 - 3rd class of use building (buildings with significant public presence, schools, theatres, museums etc.) in compliance with the Italian Seismic Code. It is a listed building.

Evaluation entailed four phases:

-  LV1 level seismic risk factor evaluation – carried out digitally using the SIVARS standard computer application for seismic risk evaluation of public heritage buildings.

- LV1 level seismic risk factor evaluation – carried out with simplified mechanical modelling as per the Italian Seismic Guidelines for Heritage Buildings;

- LV2 level seismic risk factor evaluation as per the Italian Seismic Code;

- linear analysis of the new wooden structure on the building’s south face for seismic risk.

Data sheet

  • client: Lombardy Regional Archaeological Directorate
  • location: Castelserpio (VA) archaeological park
  • activities: level LV1 and LV2 seismic hazard analysis
  • period: 2016
Archeological parksArcheological parks
Other projects

Related projects

  • Castelseprio (VA) archeological park- analysis

  • Castelseprio (VA) archeological park - structure

  • Castelseprio (VA) archeological park – pedestrian forest path

Category: Vulnerability assessment

Bridge across the Adda river in Stazzona (SO) - diagnosis and vulnerability assessment

Bridge across the Adda river in Stazzona (SO) - diagnosis an...

A diagnostic analysis was carried out aimed at characterizing and quantifying the degradation status of the bridge, as well as assessing its static structural v...

Ganda bridge in Morbegno (SO) – seismic hazard analysis

Ganda bridge in Morbegno (SO) – seismic hazard analysis

Analysis was carried out to assess static and seismic structural risk factors and was organized as follows: geometric laser scanner survey; analysis of hist...

Catholic University of “Sacro Cuore” in Milano - testing for seismic hazard analysis

Catholic University of “Sacro Cuore” in Milano -...

The diagnosis concerned the masonry and reinforced concrete structures of the Gregorianum building in the west wing of the Catholic University of Milano to anal...

FOPPOLI MORETTA E ASSOCIATI
società di ingegneria s.r.l.
Piazzetta L. Trombini 5, 23037 Tirano (SO)
C.F. / P.IVA / R.I. 00846800142
Codice INARCASSA SI002933
C.S. € 50 000 i.v

Cookie policy | Privacy Policy
Change your cookie settings

+39 0342 704827
posta@foppolimoretta.it
Reserved Area

© 2026 FOPPOLI MORETTA E ASSOCIATI
  • Home
  • Our company
  • Services
  • Portfolio
  • News
  • Video
  • Publications
  • Press review
  • Contacts

designed by IceLab