Catholic University of “Sacro Cuore” in Milano - testing for seismic hazard analysis
The diagnosis concerned the masonry and reinforced concrete structures of the Gregorianum building in the west wing of the Catholic University of Milano to analyse their seismic hazard.
The following operations were carried out:
- flat jack testing to determine the masonry stress;
- parallel flat jack testing to detect the masonry deformation characteristics;
- shear test on masonry performed with the use of flat jack with FJ-SCT technique;
- sonic testing for masonry typology detection;
- chemical - physical - petrographic analysis of mortar;
- compression tests on brickwork sampled from the masonry;
- SonReb testing for concrete resistance and compression values;
- endoscopic video inspection for the detection of small dimension masonry details;
- load testing on attic structures with the use of hydraulic jacks
Data sheet
- client: Università Cattolica del Sacro Cuore - MILAN
- location: Milan
- activities: diagnosis of seismic risk on the Gregorianum building
- period: 2015
Category: Vulnerability assessment
Ganda bridge in Morbegno (SO) – seismic hazard analysis
Analysis was carried out to assess static and seismic structural risk factors and was organized as follows: geometric laser scanner survey; analysis of hist...
Blasi Schulhaus in Basel, Switzerland - testing for seismic ...
The diagnosis was carried out in order to bring a school building up to comply seismic protection levels and was managed as follows: measurement of structura...
Old Chimney of "La Baia" residential block in Cremia (CO)
Structural diagnostics were carried out to obtain an LC3 level of knowledge as specified in the Italian Seismic Code To reach this level, geometrical surveys w...