Bridge across the Adda river in Stazzona (SO) - diagnosis and vulnerability assessment
A diagnostic analysis was carried out aimed at characterizing and quantifying the degradation status of the bridge, as well as assessing its static structural vulnerability.
Activities were planned according to the program summarized herewith:
- collection and analysis of the historical documentation available and comparison with the on site situation;
- visual inspection of conservation status and of cracking and deformation pattern;
- magnetometric analysis for the detection of rebars within R.C. beams (B.S. 1881-204:1988);
- mechanical characterisation of materials through laboratory tests such as determination of compressive strength of concrete coring and determination of traction strength of steel bars;
- extension of the results of the laboratory tests through NDT such as ultrasonic velocity measurements (UNI EN 12504-4:2005), ultrasonic tomography, pull out tests on concrete beams (UNI EN 12504-3:2005);
- determination of carbonation depth on concrete coring and on dust sampling (UNI 9944:1992 - method 2.1 and 2.3)
- mapping of corrosion potential (UNI 10174:1993);
- determination of structural stratigraphy through coring and endoscopic visual inspection.
On the basis of the information collected, the structural safety assessment was carried out, identifying the category of the bridge in compliance with the current Italian Seismic Code, and estimating the maximum allowable load the bridge can carry.
Data sheet
- client: Sondrio province
- location: Stazzona - Villa di Tirano (SO)
- activities: survey, diagnostic analysis, structural vulnerability assessment
- period: 2017
Bridges
Pedestrian wooden footbridges in Verbania - Diagnosis
The analysis was aimed at estimating the degradation of the main beams of two wooden footbridges (one made with solid wood and the other with lamellar wood) in ...
Alpini bridge in Bassano del Grappa (VI) – Health &...
In order to guarantee the highest level of overall integration, the Health & Safety plan was developed from the analysis of possible project interference co...
Ganda bridge in Morbegno (SO) – seismic hazard analysis
Analysis was carried out to assess static and seismic structural risk factors and was organized as follows: geometric laser scanner survey; analysis of hist...