Castelseprio (VA) archeological park – seismic hazard analysis
Seismic risk for the San Giovanni monastery in Castelseprio archaeological park was evaluated at level LV1 with a level LV2 integration for possible vulnerable macro-elements. A linear analysis was also carried out on the new wooden structure on the building’s south face.
The building is used mainly as a museum and exhibition space and that leads to its classification as a type 2 - 3rd class of use building (buildings with significant public presence, schools, theatres, museums etc.) in compliance with the Italian Seismic Code. It is a listed building.
Evaluation entailed four phases:
- LV1 level seismic risk factor evaluation – carried out digitally using the SIVARS standard computer application for seismic risk evaluation of public heritage buildings.
- LV1 level seismic risk factor evaluation – carried out with simplified mechanical modelling as per the Italian Seismic Guidelines for Heritage Buildings;
- LV2 level seismic risk factor evaluation as per the Italian Seismic Code;
- linear analysis of the new wooden structure on the building’s south face for seismic risk.
Data sheet
- client: Lombardy Regional Archaeological Directorate
- location: Castelserpio (VA) archaeological park
- activities: level LV1 and LV2 seismic hazard analysis
- period: 2016
Archeological parks
Castelseprio (VA) archeological park - structure
The S. Giovanni monastery in Castelseprio, until recently used as nothing more than an agricultural storage building, was returned to full use as the museum for...
Castelseprio (VA) archeological park – pedestrian fore...
The archaeological site is located on a morenic hillside, typical of the pre-alpine Lombardy landscape including some oft seen earth movement, “ceppo” local...
Castelseprio (VA) archeological park- analysis
Analysis aimed at identifying the geometric and mechanical data necessary for static characterization of the masonry of the ruins of S. Giovanni church, S. Giov...